Power Monitoring Speaker Status Read Payload
Payload emitted when the observer lambda intercepts a read of status/power_monitoring/speaker. Carries both the speaker connection presence and bell fuse integrity state.
| $id | https://schemas.texecom-prod.com/v2/events/payload/cloud/internal/power_monitoring/speaker/status_read/v1.0.0.json |
| $schema | http://json-schema.org/draft-07/schema |
Properties
serial
| Description |
Panel serial number extracted from the MQTT topic path (device/{serial}/...). |
| Type | String |
| Required |
Yes |
hardwareId
| Description |
Panel primary key in the device service DB, resolved via serial lookup (device.hardware.hardware_id). |
| Type | String |
| Required |
Yes |
| Format |
uuid |
connectionPresent
| Description |
true if speaker 12V supply is present (ADC >= threshold, default 3704); false if disconnected or wiring fault. |
| Type | Boolean |
| Required |
Yes |
connectionFault
| Description |
true if speaker connection fault is detected (ADC < threshold); false if OK. |
| Type | Boolean |
| Required |
Yes |
bellFuseOk
| Description |
true if bell fuse integrity is confirmed (ADC >= fuse threshold, default 8849). |
| Type | Boolean |
| Required |
Yes |
bellFuseFault
| Description |
true if bell fuse fault is detected (blown fuse or abnormal current; ADC < fuse threshold). |
| Type | Boolean |
| Required |
Yes |
Schema
{
"$id": "https://schemas.texecom-prod.com/v2/events/payload/cloud/internal/power_monitoring/speaker/status_read/v1.0.0.json",
"$schema": "http://json-schema.org/draft-07/schema",
"title": "Power Monitoring Speaker Status Read Payload",
"description": "Payload emitted when the observer lambda intercepts a read of status/power_monitoring/speaker. Carries both the speaker connection presence and bell fuse integrity state.",
"type": "object",
"properties": {
"serial": {
"description": "Panel serial number extracted from the MQTT topic path (device/{serial}/...).",
"type": "string"
},
"hardwareId": {
"description": "Panel primary key in the device service DB, resolved via serial lookup (device.hardware.hardware_id).",
"type": "string",
"format": "uuid"
},
"connectionPresent": {
"description": "true if speaker 12V supply is present (ADC >= threshold, default 3704); false if disconnected or wiring fault.",
"type": "boolean"
},
"connectionFault": {
"description": "true if speaker connection fault is detected (ADC < threshold); false if OK.",
"type": "boolean"
},
"bellFuseOk": {
"description": "true if bell fuse integrity is confirmed (ADC >= fuse threshold, default 8849).",
"type": "boolean"
},
"bellFuseFault": {
"description": "true if bell fuse fault is detected (blown fuse or abnormal current; ADC < fuse threshold).",
"type": "boolean"
}
},
"required": [
"serial",
"hardwareId",
"connectionPresent",
"connectionFault",
"bellFuseOk",
"bellFuseFault"
],
"additionalProperties": false
}